Full specs
Requirements
Block or Brick wall
No Drywall
No Crawlspace
Cracks, outlets, vents
Wall surfaces
If your wall is textured and has an inset larger than 1/3 of an inch, we will need to fill it up.



Compatible

If the grouts are less than 0.3"
Not
Compatible
Need
modifications


Single-Chamber FlowStop
The single-chamber FlowStop is a barrier that pushes against four walls. It has a gasket on each of the four sides.
Best used for vents, windows, or protection against waves.
Please note that your barrier will not protect against more than 42 inches of floodwater.
Specifications

-
The single-chamber pushes against four walls.
-
Gasket on four sides.
-
Customized for any height.
-
Maximum width is 275".
-
Standard depths are 6" or 8", depending on width (see depth table).
-
When a 6" FlowStop won't fit, non-standard depths are also available, depending on width (see depth table).
-
Posts can be installed to increase the depth of the opening.
Depth Table
Non-standard Depth | Non-standard Depth | Non-standard Depth | Standard Depth | ||
Width of your Flowstop | 20" to 31.5" | 31.5" to 39" | 39" to 47" | 20" to 78" | |
Flowstop Depth Minim available | 2.8" | 4" | 4.7" | 6" | |
Depth required on the wall | 1.8" | 2.6" | 3.1" | 3.9" |
Double-Chamber Flowstop
The double-chamber Flowstop is a barrier that pushes against 3 walls. It has a gasket on both sides and the bottom.
​
Best Use for Door, Windows, garage door, Large opening
Please note, your barrier will not protect against over 40" of flood water.

Specifications
-
The double-chamber pushes against 3 walls
-
Gasket on 3 sides
-
Minimum height available is 31.5"
-
Standard depths are 6" or 8", depending on Width (See Depth Table)​
-
When a 6" flowstop won't fit, non-standard depths are also available, depending on Width (See Depth Table)
-
Requires Straps after a certain Width (See Straps table)
-
Available in specific heights (See Height Table)
-
2 Chambers that inflate separately
-
Posts can be installed to increase the depth of the opening.

Depth Table
Non-standard Depth | Non-standard Depth | Non-standard Depth | Standard Depth | ||
Width of your Flowstop | 20" to 31.5" | 31.5" to 39" | 39" to 47" | 20" to 78" | |
Flowstop Depth Minim available | 2.8" | 4" | 4.7" | 6" | |
Depth required on the wall | 1.8" | 2.6" | 3.1" | 3.9" |
Height Table
If width < 60" | |||
Height available | 31.5" | 39.5" | 47.5" |
Flood water protection | 26.5" | 34.50" | 42.50" |
Strap Table
Width of the Flowstop | 78" to 95" | 95" to 135" | 135" to 275" |
# of straps required | 1 | 3 | 5 |


78" to 95"
1 STRAP
Place the strap 2" away from the valve.
95" to 135"
3 STRAPS
Add 2 straps 12" away from each edge.
Anchors tutorial

135" to 275"
5 STRAPS
Add 2 straps halfway between the central one and the one on the edge.