top of page

Full specs

Requirements

Block or Brick wall

No Drywall

No Crawlspace

Cracks, outlets, vents

Wall surfaces

If your walls are too sleek (such as aluminum or painted wood), we will apply a gripping texture to the wall to provide a better grip.

If your wall is textured and has an inset larger than 1/3 of an inch, we will need to fill it up.

12ab44be-faad-4421-ac5d-7a1a72f88833.png
589aa34b-d86c-4706-9cfe-99e5e45a8e82.jpg
7bc939c7-4237-4b0d-a964-a91949121ca8.png

Compatible

Screenshot 2025-06-15 190637.png

If the grouts are less than 0.3"

Not
Compatible

Need
modifications

Screenshot 2025-06-15 190637.png
Screenshot 2025-06-15 190637.png

Single-Chamber FlowStop

The single-chamber FlowStop is a barrier that pushes against four walls. It has a gasket on each of the four sides.
Best used for vents, windows, or protection against waves.
Please note that your barrier will not protect against more than 42 inches of floodwater.

Specifications

Screenshot 2025-06-13 121015.png
  • The single-chamber pushes against four walls.

  • Gasket on four sides.

  • Customized for any height.

  • Maximum width is 275".

  • Standard depths are 6" or 8", depending on width (see depth table).

  • When a 6" FlowStop won't fit, non-standard depths are also available, depending on width (see depth table).

  • Posts can be installed to increase the depth of the opening.

Depth Table

Non-standard Depth
Non-standard Depth
Non-standard Depth
Standard Depth
Width of your Flowstop
20" to 31.5"
31.5" to 39"
39" to 47"
20" to 78"
Flowstop Depth Minim available
2.8"
4"
4.7"
6"
Depth required on the wall
1.8"
2.6"
3.1"
3.9"

Double-Chamber Flowstop

The double-chamber Flowstop is a barrier that pushes against 3 walls. It has a gasket on both sides and the bottom.

​

Best Use for Door, Windows, garage door, Large opening

 

Please note, your barrier will not protect against over 40" of flood water.

2025-header-flowstop-desktop-1800x1200.png

Specifications

  • The double-chamber pushes against 3 walls

  • Gasket on 3 sides

  • Minimum height available is 31.5"

  • Standard depths are 6" or 8", depending on Width (See Depth Table)​

  • When a 6" flowstop won't fit, non-standard depths are also available, depending on Width (See Depth Table)

  • Requires Straps after a certain Width (See Straps table)

  • Available in specific heights (See Height Table)

  • 2 Chambers that inflate separately

  • Posts can be installed to increase the depth of the opening.

Screenshot 2025-06-15 182756.png

Depth Table

Non-standard Depth
Non-standard Depth
Non-standard Depth
Standard Depth
Width of your Flowstop
20" to 31.5"
31.5" to 39"
39" to 47"
20" to 78"
Flowstop Depth Minim available
2.8"
4"
4.7"
6"
Depth required on the wall
1.8"
2.6"
3.1"
3.9"

Height Table

If width < 60"
Height available
31.5"
39.5"
47.5"
Flood water protection
26.5"
34.50"
42.50"

Strap Table

Width of the Flowstop
78" to 95"
95" to 135"
135" to 275"
# of straps required
1
3
5
3.png
78" to 95"
1 STRAP
Place the strap 2" away from the valve.
95" to 135"
3 STRAPS
Add 2 straps 12" away from each edge.

Anchors tutorial

135" to 275"
5 STRAPS
Add 2 straps halfway between the central one and the one on the edge.
2.jpg
1.jpg
bottom of page